April 2013
Publication year: 2013
Source:Building and Environment, Volume 62
It is important to accurately model person-to-person particle transport in mechanical ventilation spaces to create and maintain a healthy indoor environment. The present study introduces a hybrid DES-Lagrangian and RANS-Eulerian model for simulating transient particle transport in enclosed environments; this hybrid model can ensure the accuracy and reduce the computing cost. Our study estimated two key time constants for the model that are important parameters for reducing the computing costs. The two time constants estimated were verified by airflow data from both an office and an aircraft cabin case. This study also conducted experiments in the first-class cabin of an MD-82 commercial airliner with heated manikins to validate the hybrid model. A pulse particle source was applied at the mouth of an index manikin to simulate a cough. The particle concentrations versus time were measured at the breathing zone of the other manikins. The trend of particle concentrations versus time predicted by the hybrid model agrees with the experimental data. Therefore, the proposed hybrid model can be used for investigating transient particle transport in enclosed environments.
► A hybrid model was proposed for modeling transient particle transport indoors. ► Two key time constants for the hybrid model were estimated and verified. ► Experiment was conducted in an MD-82 aircraft cabin to validate the hybrid model.
Publication year: 2013
Source:Building and Environment, Volume 62